RTA 460MXE Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Passerelles/contrôleurs RTA 460MXE. RTA 460MXE User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - 460MXE Gateway

460MXE Gateway User Guide 460MXE Gateway User Guide

Page 2 - Limited Warranty

Real Time Automation, Inc. 8 1-800-249-1612 460 Gateway Device Line 460MXE Modbus RTU Master Settings Now that the device is on the network you w

Page 3 - Overview

Real Time Automation, Inc. 9 1-800-249-1612 460 Gateway Device Line 460MXE Configuring External Master Modules 1) From the Main page click Edit

Page 4 - Required Tools and Data

Real Time Automation, Inc. 10 1-800-249-1612 460 Gateway Device Line 460MXE 3) Selecting any of the first four devices will install the device w

Page 5

Real Time Automation, Inc. 11 1-800-249-1612 460 Gateway Device Line 460MXE Scan List Settings 1) Data in values are values received from the Mo

Page 6

Real Time Automation, Inc. 12 1-800-249-1612 460 Gateway Device Line 460MXE BACnet IP Server Settings 1) Scroll down to the BACnet Server row an

Page 7 - Accessing the Main Page

Real Time Automation, Inc. 13 1-800-249-1612 460 Gateway Device Line 460MXE Ethernet/IP Server 1) For the Data Out column do the same as Step 8

Page 8

Real Time Automation, Inc. 14 1-800-249-1612 460 Gateway Device Line 460MXE DeviceNet Slave Settings Now that the device is on the network, you w

Page 9 - Choosing a Protocol

Real Time Automation, Inc. 15 1-800-249-1612 460 Gateway Device Line 460MXE Application Parameters 1) Next Application Parameters click Edit. 2)

Page 10 - Modbus RTU Master Settings

Real Time Automation, Inc. 16 1-800-249-1612 460 Gateway Device Line 460MXE Verifying Application Parameters 1) On the Main Page click on the St

Page 11

Real Time Automation, Inc. 17 1-800-249-1612 460 Gateway Device Line 460MXE Validating Gateway Communication If the Timeout counter or the Error

Page 12

Trademarks CompactLogix, ControlLogix, & PLC-5 are registered trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of the Open Devic

Page 13 - Scan List Settings

Real Time Automation, Inc. 18 1-800-249-1612 460 Gateway Device Line 460MXE Configuring Multiple Devices If you are configuring multiple devices

Page 14 - BACnet IP Server Settings

Real Time Automation, Inc. 19 1-800-249-1612 460 Gateway Device Line 460MXE Completing the Installation Now that the 460MXE gateway is configured

Page 15 - Ethernet/IP Server

Real Time Automation, Inc. A 1-800-249-1612 460 Gateway Device Line 460MXE Jumper Configurations To change port settings on the 460 EDX Gateway u

Page 16 - DeviceNet Slave Settings

Real Time Automation, Inc. B 1-800-249-1612 460 Gateway Device Line 460MXE Port 0 (T-Strip) CAN 1 2 3 4 5 Pin Setting GND CANL S

Page 17 - Application Parameters

Real Time Automation, Inc. 150 South Sunny Slope Road Suite 130 Brookfield WI 53005 Toll free 1-800-249-1612 Local (262) 439-4999 www.rtaautomation.

Page 18

Real Time Automation, Inc. 1 1-800-249-1612 460 Gateway Device Line 460MXE Overview The 460MXE gateway device seamlessly connects power and energ

Page 19

Real Time Automation, Inc. 2 1-800-249-1612 460 Gateway Device Line 460MXE Required Tools and Data You will need the following tools: ♦ The 460MX

Page 20 - Configuring Multiple Devices

Real Time Automation, Inc. 3 1-800-249-1612 460 Gateway Device Line 460MXE Port Connections (BACnet/IP / Modbus and Ethernet/IP / Modbus) The fac

Page 21 - Completing the Installation

Real Time Automation, Inc. 4 1-800-249-1612 460 Gateway Device Line 460MXE Port Connections (DeviceNet / Modbus) The factory default port setting

Page 22 - Jumper Configurations

Real Time Automation, Inc. 5 1-800-249-1612 460 Gateway Device Line 460MXE Accessing the Main Page Before you can configure the gateway itself yo

Page 23 - NC= No connection

Real Time Automation, Inc. 6 1-800-249-1612 460 Gateway Device Line 460MXE Error: Main Page Does Not Launch If the Main Page does not launch the

Page 24

Real Time Automation, Inc. 7 1-800-249-1612 460 Gateway Device Line 460MXE Choosing a Protocol Now that the device is on the network you will nee